Сделайте свою компанию и бизнес успешными

fluke ida 4 plus service manual

0
Голос за!

fluke ida 4 plus service manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:fluke ida 4 plus service manual.pdf
Size: 4803 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 11 May 2019, 13:35 PM
Rating: 4.6/5 from 687 votes.

Status: AVAILABLE

Last checked: 1 Minutes ago!

In order to read or download fluke ida 4 plus service manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

fluke ida 4 plus service manualAll rights reserved. Printed in USA All product names are trademarks of their respective companies. Changes made to the information in this document will be incorporated in new editions of the publication. No responsibility is assumed by Fluke Biomedical for the use or reliability of software or equipment that is not supplied by Fluke Biomedical, or its affiliated dealers. Failure to pack the instrument properly could void your warranty and result in you paying for the instrument’s repair. 3. Insure the unit for full retail value and ship to the address specified by Fluke Warnings Patient Circuit This instrument has been designed for testing infusion devices but must NEVER be used while connected to a patient. It is recommended a CE marked keyboard is used. Trademarks All trademarks mentioned in this document are acknowledged. Manufacturing for: Fluke Biomedical 6920 Seaway Blvd Everett, WA 98203 USA 775-883-3400 800-648-7952. Thank you Thank you for purchasing this instrument. It will allow you to verify the operation of your infusion devices providing measurements of volume delivered, flow rate and occlusion and backpressure. Supply Frequency 50 - 60 Hz. Supply Power Color: RAL 9002 Environmental Operational: 15-30 C up to 50 Relative Humidity. Graphic and Alphanumeric. With backlight. Up, Down, Right and Left key-pad switches Enter keypad.Three pin IEC mains inlet connection. Twin fuses integral with mains connector. Alarm Control port. 15 way. (for optional trigger interface). Parallel Printer Port. 25 way Female. Configured in the same way as a PC Printer Port. Bar Code Wand Port. Connecting Infusion Pumps under Test See Inlet Hose Connections and Outlet Hose Connections drawings. The Inlet Hose Connection drawing on the next page shows a method of connecting the inlets from units under test together with a priming syringe, both connected via a 3-way tap. These are used to operate a sequence of menus.http://flamefitnessstudio.com/cewit/images/fim-functional-independence-measure-manual.xml

    Tags:
  • fluke ida 4 plus service manual, fluke ida 4 plus service manual, fluke ida 4 plus service manual free, fluke ida 4 plus service manual pdf, fluke ida 4 plus service manual user, fluke ida 4 plus service manual download.

An optional external keyboard can also be used to control the instrument and enter data. Any time data is prompted for, the bar code port is activated. After performing initialization BIOMEDICAL procedures and self tests the instrument advances to the STATUS ALL CHANNELS screen. U T I L I T I E S Using the arrow keys to move the cursor to the required utility, in this case RECALL TESTS is selected, press ENTER and the set-up screen for the chosen utility is RECALL TESTS REPORT HEADER. Choosing ESC and pressing ENTER accepts the mode and contrast as displayed and returns the screen to STATUS ALL CHANN. T e s t P r i n t e r Test Printer Checks the link to the printer by sending the serial P r i n t S e t t i n g s. Data may Control No be entered into the fields on this screen from the Operator. From this point is possible to go Control No 12345 directly to a test or request further information. It is used to store the normal location of the device under test. Pressing ENTER from this field advances to the SUB MENU 2. ESC goes back to the Serial Number field Sub Menu2 This menu allows you to select the type of test to D e v i c e. It has a menu across the bottom of the screen FLOW 0.00 that changes to reflect the progress of the active test.It has a menu across the bottom of the screen that changes to reflect the progress of the test. It is not necessary to prime the transducer to perform an occlusion test. It C H A N N E L 1 O C C L U S I O N automatically adjusts its scale so that its maximum pressure and time are always within the axes. On completion of this field, the PCA TEST screen is invoked. Note: When testing PCA pump performance it is essential that new syringes be used. It has been observed that syringe performance degrades rapidly after about 10 uses. L a s t B o l u s A v e r a g e Auto-Start 0. L a s t B o l u s A v e r a g e Save 0. The amplitude of each spike represents the flow rate at which each bolus is V o l 3.http://hospitaldevicesindia.com/userfiles/filtro-vulcano-manual-de-uso.xml The basal flow rate should also be entered on the IDA-4 Plus. Basal Flow Only When a PCA pump is operated with the basal flow rate only, it should be tested using the normal single flow rate method. As a minimum requirement the primary flow rate will be needed. It has a menu across the bottom of the screen that changes to reflect the progress of the test. This FLOW 1 0.00 enables further menu options. C H A N N E L 1 D U A L F L O W Deviation marks as described in the single flow rate Primary graph are shown for the primary flow rate only. User Care and Maintenance Storage Do not leave water inside the unit when storing or shipping.For accurate Re-Calibration or resetting of Calibration the unit must be returned via the dealer. Users may wish to check for faults after a period of use or after shock to the unit. Gravity Controllers are powered devices which control the flow of the infusion to the desired rate by constricting the infusion line. Access by the patient to the pump itself is prevented, pre-programmed restraints are placed on the parameters of the boluses and, in addition, a basal rate delivery of solution outside the control of the patient may be provided. Pumps do not rely on gravity and can therefore be placed in almost any reasonable position relative to the infusion site (but not too high). The delivery pressure may rise to high values in some devices in the event of a catheter becoming occluded or displaced, with the danger of extra-vascular infusion. This enables the clinician to determine when and how often, a demand has been made by the patient and what total volume of drug has been infused over a given time. If these facilities are software enabled, by programming or smart card for example, in a pump that is otherwise suitable for other applications, they must be disabled before these pumps are used in any other application. Make a note as to which PC communications port the cable is connected to.http://www.familyreunionapp.com/family/events/e-flite-brio-10-manual Capabilities include receiving and sending data at baud rates of 300, 600, 1200, 2400, 4800, 9600, 19200 and 38400. The baud rate used for transmission is held in the IDA-4 Plus non-volatile memory and can be changed at any time by the operator. Sign in Forgot Password. My Bench Close Sign In Not A Member. Sign Up Join MedWrench OK name type Receive Summary Emails. This digital infusion pump tester uses fundamental measurement technology integrated with sophisticated electronics to ensure accuracy and reduce risk of human error during infusion pump testing. The IDA 4 Plus infusion pump analyzer maximizes productivity by testing up to four infusion pumps or channels at once, allowing you to move on to other tasks while letting the IDA 4 Plus takes care of infusion pump testing and documentation. The IDA 4 Plus infusion pump tester is compatible with a wide array of infusion pumps including syringe pumps, volumetric pumps and anesthesia pumps. The infusion device tester measures instantaneous flow, average flow, occlusion pressure, and analyzes patient-control analgesia (PCA) units. An optional PCA trigger box provides automated PCA pump control, allowing technicians to set up tests and walk away. An autostart feature simplifies syringe pump testing or other tests that have long startup times. With built-in memory, the IDA 4 Plus infusion device tester records infusion pump test results internally and provides easy-to-read test-result graphs live right on the analyzer’s screen. The display is so large numbers can be read from across the room. Additionally, the IDA 4 Plus infusion pump analyzer comes with Hydrograph PC software for creating full-color graphs and reports. For automated infusion pump testing, the IDA 4 Plus is compatible with Fluke Biomedical’s medTester 5000C (US only). The IDA 4 Plus Infusion Device Analyzer comes in 1-2-3- or 4-channel configurations. This allows the option of adding up to three channels to your infusion pump analyzer at a later time to meet the evolving needs of your work group. I spoke to Fluke and the version 3.50 on there website only supports IDA-1S and IDA 5 units.Please if you know some offert of used equipments.By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. All Rights Reserved. It's a portable, battery-operated analyzer that allows for easy traceability of test results without the complexity of other infusion pump testers. Key Features. Integrated carrying handle and lightweight for easy portability. Battery provides up to 10 hours of continuous performance for on-the-go operation. Compatible with a wide variety of infusion pumps. Ensures maximum accuracy with Autostart mode enabling unit to begin testing only when fluid is detected. Based on technology that is proven and trusted worldwide. On-board memory allows test results storage instantly. LCD touchscreen for ease of use. Average and instantaneous flow measurement. Occlusion pressure measurements to 45 psi. Hydrograph graphical software to control unit, display results and print results via PC. Global sales, service and support. Analyze the performance of a wide variety of infusion pumps quickly and accurately with the IDA-1S. Get real-time results using the IDA-1S one-channel infusion device analyzer, a portable, battery-operated instrument that allows accurate and quick verification of infusion device performance. The IDA-1S measures the flow rate and volume delivered, and the pressure generated in occlusions or blockages of the fluid line and is based on sophisticated measurement technology trusted by biomedical professionals around the world. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. Over the next five years, service levels will decrease due to availability of parts. Once the parts run out, the product can only be calibrated. Over time, the product has moved from elevated to severe risk due to service constraints. The higher the risk, the higher the urgency to upgrade that product. It's a portable, battery-operated analyzer that allows for easy traceability of test results without the complexity of other infusion pump testers. Key Features Integrated carrying handle and lightweight for easy portability Battery provides up to 10 hours of continuous performance for on-the-go operation Compatible with a wide variety of infusion pumps Ensures maximum accuracy with Autostart mode enabling unit to begin testing only when fluid is detected Based on technology that is proven and trusted worldwide On-board memory allows test results storage instantly LCD touchscreen for ease of use Average and instantaneous flow measurement Occlusion pressure measurements to 45 psi Hydrograph graphical software to control unit, display results and print results via PC Global sales, service and support Analyze the performance of a wide variety of infusion pumps quickly and accurately with the IDA-1S. Get real-time results using the IDA-1S one-channel infusion device analyzer, a portable, battery-operated instrument that allows accurate and quick verification of infusion device performance. The IDA-1S measures the flow rate and volume delivered, and the pressure generated in occlusions or blockages of the fluid line and is based on sophisticated measurement technology trusted by biomedical professionals around the world. The IDA-1S infusion device analyzer is easy to set up and requires little or no training to use. It can be used to analyze a wide variety of infusion pumps and the auto-start feature simplifies syringe pump testing and other tests that have long startup times. IDA-1S One-channel Infusion Device Analyzer Included accessories: Hydrograph Software and Users Manual 20 ml syringe 3-way plastic Luerlock Drain tube (1 ml) Micro-90 bottle (225 ml) USB data transfer cable Power supply accessory (country-specific) Power cord NiMH replacement battery Get Latest Price from the seller We are supported with a well equipped and advanced manufacturing unit that is managed by our team of expert professionals who are highly qualified and experienced. Our professionals use best quality tested materials for manufacturing our range. We also have a team to check the quality of our products on various attributes to offer defect free range to our clients. Get Best Deal I agree to the terms and privacy policy All rights reserved. All the manuals are intended to use by fully trained individuals and it is your responsibility to ensure that use of the website is in accordance with the laws and relevant regulations in your country. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. IDA-5 is a full-featured device that measures instantaneous flow, mean flow, occlusion flow and dual flow rate based on IEC60601-2-24. Des possibilites infinies. Learn more - opens in a new window or tab This amount is subject to change until you make payment. For additional information, see the Global Shipping Programme terms and conditions - opens in a new window or tab This amount is subject to change until you make payment. If you reside in an EU member state besides UK, import VAT on this purchase is not recoverable. For additional information, see the Global Shipping Programme terms and conditions - opens in a new window or tab Delivery times may vary, especially during peak periods and will depend on when your payment clears - opens in a new window or tab. Learn More - opens in a new window or tab Learn More - opens in a new window or tab Learn More - opens in a new window or tab Learn More - opens in a new window or tab Learn More - opens in a new window or tab The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or an item that has been returned to the seller after a period of use. See the seller’s listing for full details and description of any imperfections. Contact the seller - opens in a new window or tab and request a postage method to your location. Please enter a valid postcode. Please enter a number less than or equal to 1. You're covered by the eBay Money Back Guarantee if you receive an item that is not as described in the listing. Find out more about your rights as a buyer - opens in a new window or tab and exceptions - opens in a new window or tab. Payment. Accept Both Bank Deposit and PayPal; Payment must be received before item delivered. All Rights Reserved. User Agreement, Privacy, Cookies and AdChoice Norton Secured - powered by Verisign. Something went wrong. View cart for details.User Agreement, Privacy, Cookies and AdChoice Norton Secured - powered by Verisign. Something went wrong.Learn more - opens in a new window or tab Read item description or contact seller for postage options. This amount is subject to change until you make payment. For additional information, see the Global Shipping Program terms and conditions - opens in a new window or tab This amount is subject to change until you make payment. If you reside in an EU member state besides UK, import VAT on this purchase is not recoverable. For additional information, see the Global Shipping Program terms and conditions - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Contact the seller - opens in a new window or tab and request a postage method to your location. Please enter a valid postcode. Please enter a number less than or equal to 1. If you don't follow our item condition policy for returns, you may not receive a full refund. Refunds by law: In Australia, consumers have a legal right to obtain a refund from a business if the goods purchased are faulty, not fit for purpose or don't match the seller's description. More information at returns. All Rights Reserved. User Agreement, Privacy, Cookies and AdChoice Norton Secured - powered by Verisign. It also features quick and accurate measurement of steady or nonsteady flow patterns. Superb features are packed in this compact, lightweight body and The battery operation provides A wide load-resistance range provides 128 user-selectable loads. The Index 2XLFE is capable of Functions such as 43 arrhythmia selections. The display is bright and the housing and keypad undamaged. It responds to keypad input as it appears it should. It has not been tested beyond this. It appears to have 4 channels (see front panel pic). No software or other accessories are included. I believe it was manufactured in 2004 based on a quality control inspection sticker. There is no indication on it as to when it was last calibrated. It was in service until recently in a public health facility which usually maintains its equipment to manufacturer's specs.Returns will be accepted if a major fault is found.This digital infusion pump tester uses fundamental measurement technology integrated with sophisticated electronics to ensure accuracy and reduce risk of human error during infusion pump testing. The IDA 4 Plus infusion pump analyzer maximizes productivity by testing up to four infusion pumps or channels at once, allowing you to move on to other tasks while letting the IDA 4 Plus takes care of infusion pump testing and documentation. The IDA 4 Plus infusion pump tester is compatible with a wide array of infusion pumps including syringe pumps, volumetric pumps and anesthesia pumps. The infusion device tester measures instantaneous flow, average flow, occlusion pressure, and analyzes patient-control analgesia (PCA) units. An optional PCA trigger box provides automated PCA pump control, allowing technicians to set up tests and walk away. An autostart feature simplifies syringe pump testing or other tests that have long startup times.The display is so large numbers can be read from across the room. Additionally, the IDA 4 Plus infusion pump analyzer comes with Hydrograph PC software for creating full-color graphs and reports. For automated infusion pump testing, the IDA 4 Plus is compatible with Fluke Biomedical’s medTester 5000C (US only).Sign up now. The IDA-1S is a portable, battery-operated instrument that allows for speedy verification of infusion device performance. The IDA-1S measures the flow rate and volume delivered, and the pressure generated in occlusions or blockages of the fluid line. The IDA-1S is based on sophisticated measurement technology trusted by biomedical professionals around the world. It is easy to set up and requires little or no training to use. The IDA-1S can be used to test a wide variety of infusion pumps and an auto-start feature simplifies syringe pump testing and other tests that have long startup times. Features: Integrated carrying handle and lightweight (2.7 lb) for easy portability Battery powered with up to 10 hours of continuous operation for on-the-go operation LCD touch screen for ease of use Average and instantaneous flow measurement Occlusion pressure measurements to 45 psi Maximize accuracy with Autostart mode enabling unit to begin testing only when fluid is detected Compatible with a wide variety of infusion pumps Based on technology that is proven and trusted worldwide On-board memory allows test results storage instantly Hydrograph graphical software to control unit,display results and print results via PC Includes: Hydrograph Software and Users Manual 20 ml syringe 3-way plastic Luerlock Drain tube (1 ml) Micro-90 bottle (225 ml) USB data transfer cable Power supply accessory Power cord NiMH replacement battery. ACCU LUNG precision test lungs are used for evaluating ventilator performance according to clinical expectation and manufacturers.The coronavirus disease has spread throughout the world andAlmost half of the patients with sepsis suffer from myocardial depression.In-Person Care During Pandemic. There has been a notable increase in telemedicine use amidstFirst and only system to combine tissue acquisition, real-time imaging.According to the International Agency for Research on Cancer, in 2018.Please select channelAlmost half of the patients with sepsis suffer from myocardial depression. First and only system to combine tissue acquisition, real-time imaging. First and only system to combine tissue acquisition, real-time imaging.It is clear that the COVID-19 crisis has been a boostAccess the future of healthcare While healthcare organizations across.International experts treating COVID-19 patients have concluded that.Questions to Wolfgang Heimsch, President Customer Service at Siemens HealthineeThe 175th president of the American Medical Association (AMA). As of May 4, Oliver Reichardt isDr. Sebastian Krolop, M.D., Ph.D., M. Sc. has recently been appointed the.The American Society for Parenteral and Enteral Nutrition (ASPEN) has.The 2017 Ethica Award, the highest honour of the European cardiovascular.Gamma Medica, a leader in molecular breast imaging (MBI) technology, announced.Please select channelPlease select channel. However, as time passes, parts availability has become limited or unavailable on these units, therefore making continued support difficult. In many cases, it may be advantageous to Repair by Replacement (RBR) with new, state-of-the-art equipment. Please visit our on-line BCMarketplace for further information. An Estimate will be provided for additional repair costs if required, or a determination of repair feasibility. Please note: Calibration will be attempted on Discontinued equipment received for calibration only. In the event the item fails calibration and we are unable to adjust or repair the failure, a Failed Calibration fee shall apply. Discontinued Biomedical Test Equipment and Recommended Replacements For a complete listing of Fluke Biomedical Discontinued Products.Repairs are limited to the component(s) replaced in the original repair and not cosmetic appearance. Please Note: In some cases, we may advise that we are not be able to offer a warranty. Please send us an email and we'll get back to you, asap. All fields are required.VT PLUS HF Gas Flow Analyzer The VT PLUS HF is Fluke Biomedical’s premier general-purpose gas-flow analyzer. In addition, special display modes and bi-directional flow make it perfect for fully and efficiently testing both conventional mechanical ventilators and high-frequency ventilators. EC.6.20 now requires 100 completion of scheduled life-support device preventive maintenance every year, and VT PLUS HF can help meet those requirements. Multiple special-function tests make troubleshooting quick and efficient. VT PLUS HF has the capability to measure either high- or low-flow and pressure, replacing the need for gauges and flow meters. It measures 21 ventilator parameters and can display all of them on one screen. Results can be printed directly from the unit or from a PC with included Windows-compatible software. VT PLUS HF also has onboard graphing capability and shows the minimum, maximum, average, and absolute measurement for all parameters. Learning to use the VT PLUS HF is simple. Technicians control the unit using the VT PLUS HF user-friendly command system, or, if they’re familiar with the RT-200, they can switch to a special control mode that uses RT-200-style commands. VT PLUS HF can be operated with a variety of precision simulation lungs to ensure that ventilators are tested to manufacturers’ specifications and clinical expectations with a fully NIST-traceable testing system. Key Features. Bi-directional flow, pressure, volume, and oxygen concentration, and pressure measurements. Low- and high-pressure, and flow measurement capability. Special HF mode—up to 900 BPM (15 Hz). RS-232 and printer ports. Included Windows-compatible graphics software. All 21ventilator parameters displayed at once on one screen. Operation by user-friendly VT PLUS HF command mode or special RT-200 command mode. Minimum, maximum, average, absolute, and graph for all parameters. Multiple special-function tests for efficient troubleshooting. Optional Features. Operation with a variety of precision simulation lungs available from Fluke Biomedical to complete a fully NIST-traceable ventilator testing system. Specifications. Power. Maximum Over-Voltage:264 Vac. DisplayViewing Area:10.1 cm x 8.2 cm (3 in x 4 in). Blue on white background. Operational Modes. Manual mode, for simple tests or troubleshooting. Computer-control mode, using RS-232 serial port for special applications. Use of VT PLUS HF with VT Plus for Windows, for recording graphs and logging data to a computer. Oxygen Measurement. Range:0 to 100 . Resolution:0.1 O2. Transducer Location:Internal. Gas Compatibility. Air, O2, CO2, N2, N2O, He, mixtures or user-defined. Gas Reference Units. ATP, STPD0, STPD21 and BTPS. Output Ports. RS-232 serial port and parallel printer port. Test Parameters. Volumetric Flow. Low-Flow. Flow Range: -25 lpm to 25 lmp. Sample Rate: 100 Hz. High-Flow Dropout: 25 lpm. Breath-Detect Threshold: 2 lpm. Maximum-Flow Rate: 500 lpm. Dynamic Resistance: 10 Hz. Resolution: 0.1 mmHg. Fittings: Luer lock, stainless steel. Maximum Applied Pressure: 60 psi. Sample Rate: 100 Hz. Operating Pressure: 30 psi. Note. Fluid pressure may be applied to the positive port; however, fluids should be kept from entering the pressure port by using a suitable length of connection tubing. High-Pressure. Maximum Applied Pressure: 150 psi. Resolution: 0.1 psi. Sample Rate: 100 Hz. Fittings: DISS connector, stainless steel. Airway-Pressure. Maximum Applied Pressure: 20 psi. Please read our policies below including those on shipping BEFORE bidding!!Woonsocket, RI, USA Click to Request Price Fluke Biomedical 80K-40 Manufacturer: Fluke The Fluke 80K-40 High Voltage Probe is a high voltage probe that allows a multimeter to measure up to 40,000V respectively. Description. Email or call us. Return Policy. The Fluke Biomedical VT Plus HF is a gas-flow analyzer that can be used to test mechanical and high-frequency. Return PolicyYes No Please tell us more so that we can improve our website: How can we get in touch with you? (optional) Send Feedback Thank you for making Machinio better. Your feedback is greatly appreciated.Pacer Demand Mode Test Custom Para meters. 70 19. Normal Sinus Wave Simulation Test Custom Pa rameters. 71 20. Arrhythmia Wave Advisory Test Custom Pa rameters. 72 21. Performance Wave Simulation Test Custom Pa rameters. 73 22. ECG R-Wave Test Cu stom Parame ters. 74 23. ECG Noise Immunity Test Custom Para meters. 75 24. Battery Capacity Te st Measurem ents. 76 25. Battery Capacity Test Custom Para meters. 76 26. Defib Pulse Re petition Test M easurement s. 77 27. Defib Pulse Repet ition Test Custom Paramete rs. 77 The 700 0DP has the added capability of testing trancutaneous pacemak ers. Where the additional pacemaker testing capabi lity is applicable, this manual qualifies the description w ith “7000DP only.” The model 7000DP appears in all pr oduct illustrations. Intended Use The Analyzer is used to determine that defib rillators and transcutaneous pacemakers are performing within their performance specifications through measur ement of energy output.Safety Information In this manual, a Warning identifies hazardous conditions and actions that could cause bodily h arm or death. A Caution identifies conditions and actions that could damage the Analyzer, the equi pment un der test, or cause permanent loss of data.DEFIBRILLAT OR 5000 V p MAX 275 V MAX 1 6 2 3 4 7 5 5 8 10 11 9 fak07.eps Figure 1. Top-Panel Cont rols and Connec tions Turning the Analyzer On and Off Note Before using the Analyzer for the first time, plug the battery charger into the Analyzer and a power outlet and charge the Analyzer for at least 4 hours. Press the power button ( O ) on the top panel to turn the Analyzer on. After a short self-test period, the Analyzer will display the screen shown in Figure 3 to indicate it is ready for operation. fak01.eps Figure 3. Analyzer Ready Display Battery condition is displayed in the upp er right-hand corner of the display ( S ) when a top-level menu is displayed.